fix status is not actually a single word
This commit is contained in:
parent
3a02adde56
commit
66bc90da5c
2 changed files with 33 additions and 32 deletions
|
|
@ -113,36 +113,37 @@ async def ups_check() -> list[alerts.Alert]:
|
||||||
message=f"Battery is under {sensor.battery_warning_percentage}%\n{sensor.battery_charge_percentage}% ({timedelta(seconds=sensor.battery_runtime)} remaining.",
|
message=f"Battery is under {sensor.battery_warning_percentage}%\n{sensor.battery_charge_percentage}% ({timedelta(seconds=sensor.battery_runtime)} remaining.",
|
||||||
severity=alerts.Severity.WARNING
|
severity=alerts.Severity.WARNING
|
||||||
))
|
))
|
||||||
elif IS_TESTING or sensor.ups_status == UPSStatus.ON_BATTERY:
|
|
||||||
|
for status in sensor.ups_status:
|
||||||
|
if IS_TESTING or status == UPSStatus.BATTERY_REPLACE:
|
||||||
|
alert_list.append(alerts.Alert(
|
||||||
|
alert_type=alerts.AlertType.UPS,
|
||||||
|
message=f"UPS battery needs to be replaced ASAP!",
|
||||||
|
severity=alerts.Severity.CRITICAL
|
||||||
|
))
|
||||||
|
elif IS_TESTING or status == UPSStatus.UPS_OVERLOAD:
|
||||||
|
alert_list.append(alerts.Alert(
|
||||||
|
alert_type=alerts.AlertType.UPS,
|
||||||
|
message=f"UPS is overloaded!",
|
||||||
|
severity=alerts.Severity.CRITICAL
|
||||||
|
))
|
||||||
|
elif IS_TESTING or status == UPSStatus.UPS_BYPASS:
|
||||||
|
alert_list.append(alerts.Alert(
|
||||||
|
alert_type=alerts.AlertType.UPS,
|
||||||
|
message=f"BYPASS MODE: Battery and connected devices are not protected from power outage!",
|
||||||
|
severity=alerts.Severity.WARNING
|
||||||
|
))
|
||||||
|
elif IS_TESTING or status == UPSStatus.UPS_CALIBRATION:
|
||||||
|
alert_list.append(alerts.Alert(
|
||||||
|
alert_type=alerts.AlertType.UPS,
|
||||||
|
message=f"UPS is currently performing runtime calibration.",
|
||||||
|
severity=alerts.Severity.INFO
|
||||||
|
))
|
||||||
|
elif IS_TESTING or status == UPSStatus.ON_BATTERY:
|
||||||
alert_list.append(alerts.Alert(
|
alert_list.append(alerts.Alert(
|
||||||
alert_type=alerts.AlertType.UPS,
|
alert_type=alerts.AlertType.UPS,
|
||||||
message=f"UPS is on battery.\n{sensor.battery_charge_percentage}% ({timedelta(seconds=sensor.battery_runtime)}) remaining.",
|
message=f"UPS is on battery.\n{sensor.battery_charge_percentage}% ({timedelta(seconds=sensor.battery_runtime)}) remaining.",
|
||||||
severity=alerts.Severity.INFO
|
severity=alerts.Severity.INFO
|
||||||
))
|
))
|
||||||
|
|
||||||
elif IS_TESTING or sensor.ups_status == UPSStatus.BATTERY_REPLACE:
|
|
||||||
alert_list.append(alerts.Alert(
|
|
||||||
alert_type=alerts.AlertType.UPS,
|
|
||||||
message=f"UPS battery needs to be replaced ASAP!",
|
|
||||||
severity=alerts.Severity.CRITICAL
|
|
||||||
))
|
|
||||||
elif IS_TESTING or sensor.ups_status == UPSStatus.UPS_OVERLOAD:
|
|
||||||
alert_list.append(alerts.Alert(
|
|
||||||
alert_type=alerts.AlertType.UPS,
|
|
||||||
message=f"UPS is overloaded!",
|
|
||||||
severity=alerts.Severity.CRITICAL
|
|
||||||
))
|
|
||||||
elif IS_TESTING or sensor.ups_status == UPSStatus.UPS_BYPASS:
|
|
||||||
alert_list.append(alerts.Alert(
|
|
||||||
alert_type=alerts.AlertType.UPS,
|
|
||||||
message=f"BYPASS MODE: Battery and connected devices are not protected from power outage!",
|
|
||||||
severity=alerts.Severity.WARNING
|
|
||||||
))
|
|
||||||
elif IS_TESTING or sensor.ups_status == UPSStatus.UPS_CALIBRATION:
|
|
||||||
alert_list.append(alerts.Alert(
|
|
||||||
alert_type=alerts.AlertType.UPS,
|
|
||||||
message=f"UPS is currently performing runtime calibration.",
|
|
||||||
severity=alerts.Severity.INFO
|
|
||||||
))
|
|
||||||
|
|
||||||
return alert_list
|
return alert_list
|
||||||
|
|
|
||||||
|
|
@ -32,7 +32,7 @@ class RamSensor:
|
||||||
|
|
||||||
@dataclass
|
@dataclass
|
||||||
class UPSSensor:
|
class UPSSensor:
|
||||||
ups_status: UPSStatus = None
|
ups_status: list[UPSStatus] = None
|
||||||
battery_charge_percentage: int = None
|
battery_charge_percentage: int = None
|
||||||
battery_warning_percentage: int = 20
|
battery_warning_percentage: int = 20
|
||||||
battery_critical_percentage: int = 10
|
battery_critical_percentage: int = 10
|
||||||
|
|
@ -132,7 +132,7 @@ class Sensors:
|
||||||
case "battery.runtime":
|
case "battery.runtime":
|
||||||
sensor_data.battery_runtime = int(value)
|
sensor_data.battery_runtime = int(value)
|
||||||
case "ups.status":
|
case "ups.status":
|
||||||
sensor_data.ups_status = UPSStatus(value)
|
sensor_data.ups_status = [UPSStatus(status) for status in value.split()]
|
||||||
case _:
|
case _:
|
||||||
...
|
...
|
||||||
|
|
||||||
|
|
|
||||||